Microstop Clean cleans dry heat sterilizers and manicure instruments.
It removes combustion residue plaque from the sterilizer and gently clears instruments of plaque that appears after treatment with chemical agents or exposure to high temperatures. Instruments and equipment regain a neat appearance.
The product must not be used on items made of aluminum, non-ferrous metals, and galvanized parts.
Important: Microstop Clean is a cleaning agent, not a disinfectant. After using it, the instrument must be disinfected and sterilized.
How to clean a dry heat sterilizer:
- Make sure the dry heat sterilizer is turned off and cooled down: the surface temperature must not exceed 60 °C.
- The product is ready to use and does not need to be diluted. Apply it with a non-abrasive sponge to the surfaces that need cleaning: the inner surface of the lid, the instrument tray, kraft bag holders, and the sterilization chamber.
- Do not allow the product to get onto the heating element, thermal fuse, or temperature sensor.
- Leave for 30 minutes, then thoroughly clean the surfaces.
How to clean instruments:
- Prepare a solution in a 1:2 ratio (product : water). Add the product to the water, not the other way around.
- Immerse the instruments in the solution for 5–15 minutes.
- Rinse the instruments under running water.
The product can be used in an ultrasonic cleaner.